These inverters can be connected to Melasta Energy Storage Systems and provide the power during the power blackout and save money. These are the features
1. Self-consumption and feed-in to the grid
2. Programmable supply priority for PV, Battery or Grid
3. User-adjustable battery charging current suits different types of batteries
4. Programmable multiple operations modes: Grid tie, Off grid, and grid-tie with backup
5. Built-in Timer for various mode of on/off operation
6. Multiple communication for USB, RS-232, Modbus and SNMP
7. Monitoring software for real time status display and control
8. Custom-made firmware by ODM contract
9. Parallel operation up to 6 units for 5KW / 10KW and 15KW
MODEL
|
Solar 2KW |
Solar Plus II 3KW |
Solar Plus 5KW |
Solar 3P 10KW |
Solar 3P 15KW |
PHASE
|
1-phase in / 1-phase out |
3-phase in / 3-phase out |
|||
MAXIMUM PV INPUT POWER
|
2250 W
|
4500 W
|
10000 W
|
14850 W
|
22500 W
|
RATED OUTPUT POWER
|
2000 W |
3000 W |
5000 W |
10000 W |
15000 W |
MAXIMUM CHARGING POWER
|
1200 W
|
2880W
|
4800 W
|
9600 W
|
15000 W
|
GRID-TIE OPERATION
|
|||||
PV INPUT (DC)
|
|||||
Nominal DC Voltage / Maximum DC Voltage |
300 VDC / 350 VDC |
360 VDC / 500 VDC |
720 VDC / 900 VDC |
720 VDC / 900 VDC |
720 VDC / 900 VDC |
Start-up Voltage / Initial Feeding Voltage |
80 VDC / 120 VDC
|
116 VDC / 150 VDC
|
225 VDC / 250 VDC
|
320 VDC / 350 VDC
|
320 VDC / 350 VDC
|
MPP Voltage Range
|
120 VDC ~ 320 VDC |
250 VDC ~ 450 VDC |
250 VDC ~ 850 VDC |
400 VDC ~ 800 VDC |
400 VDC ~ 800 VDC |
Number of MPP Trackers / Maximum Input Current |
1 / 1 x 15 A
|
1 / 1 x 18 A
|
2 / 2 x 10 A
|
2 / 2 x 18.6A
|
2 / A: 37.65A; B: 18.6A
|
GRID OUTPUT (AC)
|
|||||
Nominal Output Voltage
|
101/110/120/127 VAC
|
208/220/230/240 VAC
|
230 VAC (P-N) / 400 VAC (P-P)
|
||
Output Voltage Range
|
88 - 127 VAC* |
184 - 265 VAC* |
184 - 265VAC* per phase |
184 - 264.5VAC per phase |
|
Nominal Output Current
|
18 A
|
13 A
|
21 A
|
14.5A per phase
|
21.7A per phase
|
Power Factor
|
> 0.99 |
||||
EFFICIENCY
|
|||||
Maximum Conversion Efficiency (DC/AC) |
95%
|
96%
|
|||
European Efficiency@ Vnominal
|
94%
|
95%
|
|||
OFF-GRID OPERATION
|
|||||
AC INPUT
|
|||||
AC Start-up Voltage/Auto Restart Voltage |
60 - 70 VAC / 85 VAC |
120 - 140 VAC / 180 VAC |
120 - 140 VAC per phase / 180 VAC per phase |
||
Acceptable Input Voltage Range
|
80 - 130 VAC
|
170 - 280 VAC
|
170 - 280 VAC per phase
|
||
Maximum AC Input Current
|
30 A
|
40 A
|
|||
PV INPUT (DC)
|
|||||
Maximum DC Voltage
|
350 VDC |
500 VDC |
900 VDC |
900 VDC |
900 VDC |
MPP Voltage Range
|
150 VDC ~ 320 VDC
|
250 VDC ~ 450 VDC
|
250 VDC ~ 850 VDC
|
400 VDC ~ 800 VDC
|
350 VDC ~ 850 VDC
|
Number of MPP Trackers/Maximum Input Current |
1 / 1 x 15 A |
1 / 1 x 18 A |
2 / 2 x 10A |
2 / 2 x 18.6A |
2 / A: 37.65A; B: 18.6A |
BATTERY MODE OUTPUT (AC)
|
|||||
Nominal Output Voltage
|
101/110/120/127 VAC |
208/220/230/240 VAC |
202/208/220/230/240 VAC |
230 VAC (P-N) / 400 VAC (P-P) |
230 VAC (P-N) / 400 VAC (P-P) |
Output Waveform
|
Pure Sinewave
|
||||
Efficiency (DC to AC)
|
90%
|
93%
|
91%
|
91%
|
|
HYBRID OPERATION
|
|||||
PV INPUT (DC)
|
|||||
Nominal DC Voltage / Maximum DC Voltage |
300 VDC / 350 VDC
|
360 VDC / 500 VDC
|
720 VDC / 900 VDC
|
720 VDC / 900 VDC
|
720 VDC / 900 VDC
|
Start-up Voltage / Initial Feeding Voltage |
80 VDC / 120 VDC |
116 VDC / 150 VDC |
225 VDC / 250 VDC |
320 VDC / 350 VDC |
320 VDC / 350 VDC |
MPP Voltage Range
|
150 VDC ~ 320 VDC
|
250 VDC ~ 450 VDC
|
250 VDC ~ 850 VDC
|
400 VDC ~ 800 VDC
|
350 VDC ~ 850 VDC
|
Number of MPP Trackers/Maximum Input Current |
1 / 1 x 15 A |
1 / 1 x 18 A |
2 / 2 x 10A |
2 / 2 x 18.6A |
2 / A: 37.65A; B: 18.6A |
GRID OUTPUT (AC)
|
|||||
Nominal Output Voltage
|
101/110/120/127 VAC |
208/220/230/240 VAC |
202/208/220/230/240 VAC |
230 VAC (P-N) / 400 VAC (P-P) |
230 VAC (P-N) / 400 VAC (P-P) |
Output Voltage Range
|
88-127 VAC*
|
184 - 265 VAC*
|
184 - 265 VAC*
|
184 - 264.5 VAC
|
|
per phase |
per phase |
||||
Nominal Output Current
|
18 A
|
13 A
|
21 A
|
14.5 A per phase
|
21.7A per phase
|
AC INPUT
|
|||||
AC Start-up Voltage / Auto Restart Voltage |
60 - 70 VAC / 85 VAC
|
120 - 140 VAC / 180 VAC
|
120 - 140 VAC per phase
|
120 - 140 VAC per phase
|
|
/ 180 VAC per phase |
/ 180 VAC per phase |
||||
Acceptable Input Voltage Range
|
80 - 130 VAC
|
170 - 280 VAC
|
170 - 280 VAC per phase
|
170 - 280 VAC per phase
|
|
Maximum AC Input Current
|
30 A
|
40 A
|
40 A
|
||
BATTERY MODE OUTPUT (AC)
|
|||||
Nominal Output Voltage
|
101/110/120/127 VAC |
208/220/230/240 VAC |
202/208/220/230/240 VAC |
230 VAC (P-N) / 400 VAC (P-P) |
230 VAC (P-N) / 400 VAC (P-P) |
Efficiency (DC to AC)
|
90%
|
93%
|
91%
|
91%
|
|
BATTERY & CHARGER
|
|||||
Nominal DC Voltage
|
48 VDC
|
||||
Maximum Charging Current
|
Default 25A, 5A - 25A (Adjustable) |
Default 25 A, 5A - 60A (Adjustable) |
Default 60A, 5A - 100A (Adjustable) |
Default 60A, 10A - 200A (Adjustable) |
Default 60A, 5A - 300A (Adjustable) |
GENERAL
|
|||||
PHYSICAL
|
|||||
Dimension, D x W x H (mm)
|
107 x 438 x 480
|
204.2 x 460 x 600
|
167.2 x 500 x 622
|
219 x 650 x 820
|
|
Net Weight (kgs)
|
15.5
|
29
|
40
|
62
|
|
INTERFACE
|
|||||
Communication Port
|
RS-232/USB
|
RS-232/USB
|
RS-232, USB and |
||
Dry contact
|
|||||
Intelligent Slot
|
Optional SNMP, Modbus and AS-400 cards available |
||||
ENVIRONMENT
|
|||||
Humidity
|
0 ~ 90% RH (Non-Condensing) |
||||
Operating Temperature
|
0 to 40°C
|
-10 to 55°C
|
|||
Altitude
|
0 ~ 1000 m** |